How do you program the test timer?   (ID:13994466)
The following will explain how to enable the test report on the Vista-15P/20P.

 

Watch out for:

·        Program the test report code: *64.

·        Periodic test report schedule: Automatic schedule

·        Periodic test report schedule: Manual schedule

·        Split reporting: *49

·        Verify that the panel is able to send other signals.

·        Try to send a manual test report.

 

 

Program the test report code: *64.

*64 is the test report code. It is a 2-digit entry.

If the first digit is 0, the test report is disabled.

If the first digit is any other entry, the rep[ort is enabled.

 

 

Periodic test report schedule: Automatic schedule

For panel with Rev 2 or higher, you can use the Automatic Periodic test command to load the test schedule. Transmission will start 12 hours after the command is entered.

Installer code + [#] + 0 + 0: Daily test (every day)

Installer code + [#] + 0 + 1: Weekly test (7 days)

Installer code + [#] + 0 + 2: Monthly test (28 days)

 

 

Periodic test report schedule: Manual schedule

The report must be enabled in scheduling (Under relay programming in Compass)

Do the following from OUTSIDE PROGRAMMING:

Ø       Press Installers code + [#] + 64, the screen displays ‘Enter Schedule #’

Ø       Enter schedule numbers 01-32 for installer functions. (Use #4-8 on 15P; 17-32 on 20P)

Ø       Press [*] to continue

Ø       The screen displays ‘Clear Event’ Enter 11 for test report then

Ø       Press [*] to continue

Ø       Program the test start time. (Use  [1] or [3] to change AM to PM) Press [*] to advance across the screen. Enter 1 to enable each day & 0 to disable. If you want a report to send every 24 hours enter 1 for every day, otherwise select ONLY 1 day.

Ø       Press [*] to continue.

Ø       Screen displays ‘Repeat Option’ enter 0 for no repeat, 1 for weekly, 2 for bi-weekly, 3 for every 3 weeks, or 4 for every 4 weeks.

Ø       Press [*] to continue

Ø       Screen displays ‘Randomize’, if this is selected the scheduled start time will vary within 60 minutes of the hour time.  NOTE:  This is NOT recommended for test reporting.

Ø       Press [*] to continue. 

Ø       Screen displays ‘Enter Schedule #’. Press 00 to exit the menu mode.

 

 

Split reporting: *49

This filed may send alarms to the primary number, but test reports to the secondary number. If you don’t have a secondary phone number, or your secondary account number is not correct, you will get alarms, but not test.

In general, you probably want *49 = 0.

 

 

Verify that the panel is able to send other signals.

Activate an alarm (or other signal) to verify that basic communication setup is correct.

 

 

Try to send a manual test report.

At the keypad, key the installer code + 5 +1.

SYSTEM MUST BE READY with no bypassed zones (communicator can not be active)

If the test is successful, Keypad will display "Phone Okay" or "Cd" on Fixed English Keypads.

If this test fails the keypad will display "Comm Failure" or FC on fixed-English keypads.

To exit this mode hit Installers code + off.